Hielscher Ultrasonics
We will be glad to discuss your process.
Call us: +49 3328 437-420
Mail us: info@hielscher.com

Using Sonicators in Specialized Enclosures

Sonicators made by Hielscher can be used in specialized atmospheres, such as anaerobic enclosures, fume hoods, glove boxes, or purged cabinets. These controlled environments allow for precise manipulation of oxygen levels, humidity, and reactive gases, while also offering explosion protection in hazardous settings.

Why Sonication in Specialized Enclosures Matter

Specialized enclosures create unique atmospheres that help preserve sample integrity and ensure personnel safety. Sonication often involves processes that use solvents, or that can generate aerosols, vapor, or reactive byproducts. By combining Hielscher sonicators with a properly designed enclosure, you can fine-tune these parameters and carry out demanding applications with minimal risk or exposure.

  • Anaerobic Enclosures: Designed for low-oxygen or oxygen-free environments, these chambers protect oxygen-sensitive cultures and help maintain the vitality of anaerobic microbes.
  • Fume Hoods: Equipped with efficient ventilation, fume hoods capture toxic or flammable fumes and vapors produced during sonication, ensuring a safer laboratory workspace.
  • Glove Boxes: Ideal for handling air-sensitive or moisture-sensitive substances, glove boxes prevent sample oxidation or contamination while enabling hands-on sonication.
  • Purged Cabinets: Used in explosion-prone settings, purged cabinets maintain a steady flow of inert gas, minimizing ignition risks when working with volatile compounds.
  • Sound Enclosures: Designed to reduce noise levels from high-intensity ultrasonic processes, these enclosures dampen sound waves and create a more comfortable working environment.
Sonicator for Tobacco Extraction using Hexane

Sonicator for Solvent Extraction in Fume Hood

Sonicators in Anaerobic Enclosures

Anaerobic enclosures create an oxygen-free environment. Even small amounts of oxygen can disrupt microbial growth or spoil sensitive enzymes during fermentation or culture steps. Hielscher sonicators use cavitation to speed cell breakdown and increase extraction yields. Consequently, these devices help retrieve oxygen-sensitive enzymes, break down anaerobic microbes, and homogenize samples that degrade under oxygen exposure.

Advantages of Sonication in Fume Hoods

Fume hoods serve two vital purposes in sonication. First, they protect staff from harmful fumes and vapors. Second, they maintain a well-ventilated work zone. When reactive chemicals or volatile solvents are present, the hood pulls fumes away from operators, thus reducing flammable or toxic vapor buildup. Moreover, fume hoods are useful for mixing solvent-based solutions, breaking apart reactive organic compounds, and tackling unpleasant odors during emulsification.

Glove Boxes for the Sonication of Air- and Moisture-Sensitive Materials

Glove boxes keep humidity and oxygen levels very low. They are essential for working with pyrophoric substances, reactive metal powders, or battery parts. Placing a Hielscher sonicator in a glove box can improve nanoparticle mixing in low-oxygen conditions and aid in preparing reactive slurries for batteries or fuel cells. Consequently, glove boxes also help protect fragile reactions from unwanted moisture or oxygen damage.

Sonicators in Purged Cabinets for Explosion Protection

Purged cabinets are used when explosive gases or dusts may occur during sonication. They rely on non-reactive gas purges to limit ignition risks and thus allow safe operation with high-power devices like the UIP1000hdT or UIP2000hdT. These cabinets are popular for extracting plant oils that release flammable vapors, managing solvents that create explosive fumes, and shielding industrial sonication setups from sudden pressure changes.

Information Request




Note our privacy policy.




Typical Sonication Processes in Controlled Environments

General Guidelines for Safe Sonicator Operation

Below are standard recommendations for using sonicators in enclosures. For more details, please contact our technical team. We will gladly share specific advice!

  • Keep ambient gas pressure between 700 hPa and 1200 hPa at all times.
  • Limit pressure changes to no more than 100 hPa per hour, even if the sonicator is off.
  • Use proper grounding and static discharge measures, especially in explosive environments.
  • Track the enclosure temperature to avoid overheating or sample damage.
  • Establish an SOP that covers pressure checks, gas purging, and emergency shutdowns.

Hielscher Sonicators for Your Process Needs

Hielscher sonicators work well with anaerobic enclosures, fume hoods, glove boxes, and purged cabinets. Researchers and process engineers can thus tackle sensitive or hazardous tasks with confidence. By monitoring ambient gas pressure and preventing rapid pressure shifts, you maintain both safety and consistent performance. Whether you need an oxygen-free environment, advanced fume management, low-humidity conditions, or explosion protection, contact us for further guidance. We can recommend the best sonicator setup and provide helpful operating tips.

Information Request




Note our privacy policy.






Effect of Gas Composition and Pressure on Heat Dissipation

Heat dissipation during sonication depends on the ambient gas and pressure. The sonicator produces heat through mechanical motion and electrical conversion, while the sample warms from cavitation and friction. Under normal atmospheric conditions, most of this heat leaves via convection, forced air, and radiation. However, specialized atmospheres, such as anaerobic enclosures or purged cabinets, bring added factors into play.

Different gases vary in how they transfer heat. Non-reactive gases like argon or nitrogen often conduct heat less efficiently than air. Consequently, poor ventilation can trap more heat in the chamber. Meanwhile, slightly pressurized environments improve convection and heat flow, which stabilizes operating temperatures. Conversely, pressure levels near 700 hPa can weaken cooling, causing temperature spikes in the sonicator or the sample. Therefore, fans or external cooling help reduce heat accumulation. Still, the type of gas impacts how easily heat spreads. Regularly checking sample and enclosure temperatures improves consistency and protects both the samples and the ultrasonic equipment.


Sonication in Enclosures FAQs

Why is it important to keep the ambient gas pressure between 700 hPa and 1200 hPa?
This range, even when the sonicator is off, prevents strain on the enclosure and the ultrasonic equipment. It also supports stable cavitation and reliable results.

Can rapid pressure fluctuations damage the sonicator?
Yes. Ambient gas pressure changes over 100 hPa per hour can harm the sonicator electronics and seals, causing failures or inaccurate readings.

What advantages do I gain by installing a sonicator in a fume hood?
A fume hood removes harmful or flammable vapors created during ultrasonic processing, which helps reduce risks and maintain a safer lab.

Can glove boxes accommodate large-scale sonication?
Yes, if the box is sized and designed for the process scale. Hielscher provides various power levels to meet specific throughput demands.

Are purged cabinets only necessary for explosive atmospheres?
They mainly help in explosive or flammable conditions, but they also support reactive processes by ensuring a stable, non-reactive environment.

How does gas composition influence sonication efficiency?
Gas type affects heat flow and ultrasonic cavitation. Non-reactive gases like argon or nitrogen can change cooling and overall processing results.

What are typical applications of sonication in anaerobic environments?
Anaerobic sonication is useful for extracting oxygen-sensitive enzymes, breaking down anaerobic microbes, and working with materials prone to oxygen damage.

Do I need special ventilation in a glove box for sonication?
Most glove boxes have circulation and filtration systems. Ensure they can handle the extra heat from the sonicator and any vapors created.

How can I minimize heat buildup when sonicating in a sealed enclosure?
Use fan-assisted or external cooling. Also, watch enclosure temperatures, adjust sonication power as needed, and keep pressure levels steady to ensure consistent results.

We will be glad to discuss your process.

Let's get in contact.