Hielscher faka'ata tekinolosia

Sipinga ʻo e teuteu mo e Ultrasonic VialTweeter

ʻE lava ke fie maʻu ha sipinga ʻo e teuteu kimuʻa pea toki ʻanalaiso ngaahi meʻa ngaahi founga kehekehe hange ko e homogenization, lysis, toʻo hingoa ʻo e polotini, DNA, RNA, organelles mo e ngaahi meʻa intracellular kehe, ʻo fakaleleiʻi mo degassing. Ko e VialTweeter ko ha meʻangaue makehe ultrasonic ia ʻoku ne teuteuʻi ha ngaahi sipinga lahi ʻi he taimi tatau pe. Koeʻuhi ko e sonication ʻoku ʻikai fakahangatonu ai ʻa e tiupi, ʻoku taʻofi ai ʻa e fakaʻuliʻi mo e sipinga ʻo e mole.

Sipinga 'o ha ultrasonic teuteu

Ultrasonication is a common technique of sample treatment in order to get the sample ready for analyses such as polymers chain reaction (PCR), Western Blots, assays, molecular sequencing, chromatography etc. Ultrasonication is a technique widely used in laboratories to treat samples pre-analytically. A major advantage of sonication is that the working principle of ultrasound is based on purely mechanical forces. Ultrasonic lysis and cell disruption is achieved by sonomechanical shear forces, which gives ultrasonication the advantage that the solvents used for protein extraction can be used also during lysis. Ultrasonic cell disruptors such as the VialTweeter break the cell walls / membranes and promote mass transfer between cell interior and solvent. Thereby, the analyte (e.g. DNA, RNA, proteins, organelles etc.) are efficiently transferred from the cell matrix into the solvent. This means the steps of quenching and extraction overlap with the ultrasonic cell disruption process, which makes ultrasonic lysis very effective. Furthermore, ultrasonic sample preparation does not require detergents and other lysis reagents, which might alter and destruct the structure of the lysate and is known for the subsequent troubles with purification. Another lysis method, the enzymatic disruption requires long incubation times and delivers often non-reproducible results. Ultrasonic sample preparation overcomes common problems in sample preparation such as tissue homogenization, cell disruption, lysis, protein extraction and lysate solubilization. Since the intensity of the ultrasonic treatment can be exactly controlled and adjusted to the biological sample, degradation and sample loss are avoided. Automatically monitored and controlled sample temperature, pulse mode and sonication duration ensure optimum outcomes.

Ko e VialTweeter ko ha founga makehe ultrasonic ia ki he hoko sonication 'o a'u ki he ngaahi tukunga tatau 'e 10 'o 'ikai 'uli'i.

UP200St mo e VialTweeter ma'a Sonication 'o e closed

ʻOku matuʻaki faingamalie ʻa e VialTweeter ki he ngaue ki he fale fakakemi ʻa ia ʻoku fie maʻu ki ai ʻa e teuteu hoko ʻo ha ngaahi sipinga kehekehe ʻi he tuʻunga tatau pe. Ko e VialTweeter ko ha konga ultrasonic sonotrode te ne lava ʻo pukepuke hake ki ha foʻi vaia ʻe 10 (e.g. Eppendorf, centriguge, NUNC tiupi, cryo-foʻu) pea sonicates kinautolu ʻi he ngaahi tuʻunga ʻoku puleʻi totonu. Koeʻuhi ʻoku o fakataha ʻa e ivi ultrasonic ʻi he ngaahi holisi ʻo e foʻi ʻaa ki he sipinga Lotoloto, ʻoku kei tapuni pe ʻa e ngaahi foʻi ʻa ʻi he lolotonga hono faitoʻo. ʻI heʻene pehee, ʻoku fakaʻehiʻehi ʻaupito ai ʻa e sipinga ʻo e mole mo e fakaʻuliʻi.

Fakakakato 'a e fokotu'utu'u 'o e VialTweeter: VialTweeter sonotrode 'i he ultrasonic processor UP200St

Ultrasonic teuteuʻi ʻe he sipinga ʻa e ʻiuniti VialTweeter: VialTweeter sonotrode ʻi ultrasonic processor UP200St

Kole 'a e fakamatala




Fakatokanga'i ange 'etau Tu'utu'uni totonu fakatautaha.


ʻOku taau ʻa e vials mo e tiupi mo e VialTweeter

ʻOku feʻunga ʻa e VialTweeter ke maʻu ha tiupi angamaheni ʻe 10 conical pe ʻi lalo hange ko Eppendorf, centrifuge, cryo-hina mo e ngaahi faʻahinga kehekehe ʻo e NUNC, ka ʻe lava pe ke fakapatonu ʻa e ngaahi ava ki ha hina mo ha foʻi tiupi kehe ʻi he kole. Kataki ʻo fakaha mai ke mau ʻiloʻi pe ko e fe ʻa e faʻahinga tiupi sivi ʻoku ke fie fakaʻaongaʻi koeʻuhi ke mau lava ʻo liliu hoʻo VialTweeter ʻo fakatatau ki ai. Ki ha ngaahi tiupi sivi lahi ange hange ko Falcon tiupi mo e ngaahi kane sivi kehe, beakers mo e ngaahi vaka, ko e VialPress ko ha founga lelei ia.

Ko e VialTweeter mo VialPress

VialTweeter 'a e Hielscher mo e VialPress ma'a e Sonication 'ikai fakahangatonu 'o e Vials lahi angeLolotonga ia ʻoku ʻosi hoko ʻa e VialTweeter mo hono ngaahi luo tiupi ʻe 10 ko ha meʻangaue makehe mo lelei ultrasonic, ʻoku hanga ʻe he VialPress tanaki atu ʻo ʻai ke toe mahuʻinga ange ʻa e VialTweeter mo faingofua ange hono fakalele. Ko e VialPress ko ha masani ia ki he VialTweeter ʻoku kau ʻi ha pa clamp ʻoku lava ke ne fakaleleiʻi ha ngaahi tiupi lahi ange hange ko Falcon tiupi pe ko ha kiʻi sivi siʻisiʻi ki he kongaloto beakers ki he VialTweeter ʻi muʻa. ʻOku ha ʻi he fakatata ʻi toʻohema ʻa e VialTweeter ʻoku ne pukepuke ʻa e foʻi tiupi Eppendorf ʻe 10 ʻi he konga folofola, lolotonga ia ʻoku fixates ʻe he VialPress ha foʻi leta sivi lahi ange ki muʻa ʻi he sonication. ʻOku lava ʻa e VialPress ʻo hiki hake ki ha tiupi sivi lahi ange ʻe 5 ki ha sonication lahi.

VialTweeter sipinga ʻo e teuteu ke fai

ʻOku lahi hono fakaʻaongaʻi ʻo e VialTweeter ki he ngaahi sipinga totonu. Kimuʻa pea fai hono ʻanalaiso, kuo pau ke teuteuʻi ʻa e ngaahi sipinga ki he biochemical pe biophysical pehe mo e pehe, hange ko e lysis, homogenization, ivi toʻo ʻuli, DNA/RNA, degassing etc. ʻOku fulfils ʻe he VialTweeter ʻa e ngaahi founga ultrasonic ko ʻeni reliably mo fakahaofi reproducible ngaahi ola. Ko hono fakaʻaongaʻi angamaheni ʻo e VialTweeter ko e lysis/fakahohaʻasi toʻotoʻo ia ʻo e mammalian (tangata mo e monumanu) pea pehe ki he ngaahi selo ʻo e pekitilia mo e viral. ʻOku kau ʻi he ngaahi sipinga totonu ʻo e VialTweeter ʻa e maʻamaʻa ʻo e tangata epithelial e ngaahi selo, haematopoietic e ngaahi selo, myeloid e ngaahi selo ʻo e kanisa toto, Escherichia kololi, Subtilis 'o e bacillus, Bacillus anthracis, Francisella tularensis, Yersinia pestis, Streptococcus pyogenes, Caulobacter crescentus, Mycoplasma pneumoniae, mycobacteria/Mycobacterium tipii fihi (MTBC) mo ha ngaahi hangatamaki kehe, botanical, mo microbial ngaahi selo.
ʻI lalo, te ke lava ʻo maʻu ha niʻihi tokosiʻi kuo fili ʻoku ʻasi ai ʻa e VialTweeter.

The VialTweeter can hold up to 10 common test vials for simultaneous ultrasonic sample preparation

Ko e VialTweeter sonicates 1.0, 1.5 mo 2.0 mL Eppendorf tiupi ʻi he malohi lahi ʻo ʻikai ha fakaʻuliʻi pe sipinga ʻo ha mole.

VialTweeter Applications

  • Tohituku Homogenization
  • To'oto'o 'a e faingata'a & lysis
  • Polotiini to'o e 'uli
  • DNA/RNA tele fulufuluʻi
  • pellet toʻotoʻo solubilization
  • pathogen fakatokanga
  • Degassing
  • ʻi he diagnostics
  • faitoʻo ngaahi meʻa kimuʻa
  • Proteomics

E. kololi Lysis mo VialTweeter ki he-Vivo Glutathione loto fakapapau

Naʻe tupu ʻa Escherichia kololi ʻo e faingataʻaʻia MG1655 ʻi he MOSAME ʻi ha voliume fakakatoa ʻo e 200ml kae ʻoua kuo aʻu ki ha A600 ʻo e 0.5. Naʻe vahevahe ʻa e anga fakafonua ki he ngaahi anga fakafonua ml ʻe 50 ki hono faitoʻo ʻo e loto mafasia. Hili ha miniti ʻe 15 ʻo e incubation mo e 0.79 mM allicin, 1 mM diamide, pe dimethyl sulfoxide (mapuleʻi), naʻe toli ʻa e ngaahi selo ʻi he 4, 000g ʻi he 4 ° c ʻi ha miniti ʻe 10. Naʻe tuʻo ua hono fufulu ʻo e ngaahi selo ʻaki ʻa e KPE ngataʻanga kimuʻa pea resuspension ʻa e pellets 700μl ʻo e KPE ngataʻanga. Ki he deproteination, naʻ 300μl a e ʻesiti ʻo e 10% (w/v) sulfosalicylic ʻesiti kimuʻa pea toki fakahohaʻasi e ngaahi selo ʻe ultrasonication (miniti ʻe 3 x 1; VialTweeter ultrasonicator). Naʻe tanaki Supernatants hili centrifugation (miniti ʻe 30, 13, 000g, 4 °C). Naʻe holo ʻa e Sulfosaliclic ʻesiti concentrations ki he 1% ʻaki hono tanaki atu ʻo e voliume ʻe 3 ʻo e KPE ngataʻanga. Naʻe fakahoko ʻa e fua ʻo e glutathione fakakatoa mo e GSSG ʻo hange ko hono fakamatalaʻi ʻi ʻolunga. Naʻe fikaʻi ʻa e glutathione Mopaila concentrations ʻo makatuʻunga ʻi ha tohi ʻa E. kololi ngaahi selo ʻo e 6.7×10-15 pea mo ha density toʻotoʻo ʻo e A600 0.5 (tatau mo e ngaahi selo ʻe 1×108 ml-1). Naʻe fikaʻi ʻa e GSH concentrations ʻe he malohi ʻo e 2 [GSSG] mei he glutathione fakakatoa. (Müller et Al. 2016)

Lysis toʻotoʻo mo VialTweeter kimuʻa pea Graphite fonise afi ʻatomi Absorption Spectrometry

Naʻe fehangahangai ʻa Bacillus subtilis 168 (trpC2) mo ha miniti ʻe 15 ʻo antibiotic loto mafasia, Pea toki toli leva ʻa e ngaahi selo ʻi he 3,320 x g, fufulu tuʻo nima mo e 100 mM Tris/1 mM EDTA, pH 7.5, resuspended ʻi he 10 mM Tris, pH 7.5 pea motuhia ʻe ultrasonication ʻi ha meʻangaue Hielscher VialTweeter. (Wenzel et Al. 2014)

VialTweeter sipinga ʻo e teuteu kimuʻa pea toki Spectrometry

Naʻe resuspended ʻa e lyophilized toʻotoʻo pellets ʻo e CD34 ʻa e tangata􏰀 hematopoietic/progenitor ngaahi selo ʻi he 10μ􏰇l (200μl ki he teuteu lalahi HEK293 ki he peptide fakalanulei) ʻo e 8 M uRea ʻi he 100 mM ammonium fakapaaki ʻo e carbonate mo lysed tokoniʻi ʻe sonication mo e Hielscher VialTweeter ʻi ha amplitude ʻo e 60%, ko ha siakale ʻo e 60% mo e loloa ʻo e taʻu 20 ʻi he mokomoko ʻo ʻi he ʻaisi. (Amon et Al. 2019)

Sipinga ʻo e teuteu ke fakaʻaongaʻi ʻa e VialPress

The VialTweeter equipped with VialPress, a clamp that fixates larger test vessel to the VialTWeeter front for intense indirect sonicationNaʻe homogenized ʻa e lettuce foʻou (Lactuca sativa) ʻi he 0.5 M HEPES ngataʻanga (pH 8, KOH fakatonutonu) ʻi ha fika (mamafa foʻou) ki he 200, 100, 50, pe 20 mL founga fakaleleiʻi. Naʻe kehekehe pe ʻa e fika fehangahangai ʻo e fuʻu ʻakau ke fakaleleiʻi ʻaki ʻa e tohi homogenate fakakatoa ʻi he vahaʻa ʻo e 3.5 mo e 12 mL. Naʻe kehekehe pe ʻa e fika fehangahangai ʻo e fuʻu ʻakau ki he ngaahi founga fakaleleiʻi ʻo e homogenate ʻi he vahaʻa ʻo e 3.5 mo e 12 mL, ʻo fakaʻata homogenization mo e fekumi. Homogenates leva ʻa e ultrasonication ʻo fakaʻaongaʻi ha UP200St mo VialTweeter fakanaunau ʻaki ʻa e 200xt VialPress (Hielscher Ultrasonics GmbH, Siamane) ʻi ha miniti ʻe 3 (80% sepo mo e 100%). Naʻe fakaʻehiʻehi mei hono fakaʻaongaʻi ʻo e meʻangaue ko ʻeni ke (Laughton et Al. 2019)

Kole 'a e fakamatala




Fakatokanga'i ange 'etau Tu'utu'uni totonu fakatautaha.


VialTweeter at the ultrasonic processor UP200ST

Ko e VialTweeter mo e 10 Eppendorf ʻi he ultrasonic processor UP200St

Mapuleʻi falalaʻanga ʻo e ʻea lolotonga Sonication mo e VialTweeter

Ko e mafana ʻo e ʻea ko ha meʻa mahuʻinga ia ʻoku matuʻaki mahuʻinga ki hono faitoʻo ʻo e ngaahi sipinga totonu. ʻI he hoko ʻa e sipinga fakamisini kotoa pe, ʻoku fakatupu ʻe sonication ha vela. Neongo ia, ʻe lava ke mapuleʻi lelei e mafana ʻo e ngaahi sipinga ʻi he taimi ʻoku fakaʻaongaʻi ai e VialTweeter. ʻOku mau ʻoatu ha ngaahi fili kehekehe ke vakaiʻi mo puleʻi ʻaki e mafana hoʻo sipinga lolotonga hono teuteuʻi kinautolu ʻaki e VialTweeter mo e VialPress ke ʻanalaiso.

  1. Vakaiʻi ʻa e sipinga ʻo e ʻea: ko e ultrasonic processor UP200St, ʻa ia ʻoku ne teke ʻa e VialTweeter, ʻoku fakanaunau ʻaki ia ha polokalama fakakomipiuta fakapotopoto mo ha mafana pluggable sensor resistance. Palaki ʻa e mafana ʻo e ʻea sensor resistance ki he UP200St pea fakahu ʻa e tokoni ʻa e ʻea sensor resistance ʻi he taha ʻo e ngaahi sipinga ʻo e tiupi. ʻI he naunau fakaʻilekitulonika coloured, te ke lava ʻo fokotuʻu ʻi he menu ʻo e UP200St ha mafana pau ki hoʻo sipinga sonication. ʻE taʻofi leva ʻa e ultrasonicator ʻi he taimi ʻe aʻu ai ʻa e mafana ʻo e ʻea pea kiʻi malolo kae ʻoua kuo aʻu ʻa e sipinga ʻo e ʻea ki he tuʻunga ʻulungaanga mahuʻinga maʻulalo ange ʻo e mafana ʻo e ʻ∆ mafana. Pea toe kamata leva ʻa e sonication. ʻOku taʻofi ʻe he founga fakapotopoto ko ʻeni ʻa e maʻulalo ʻoku ne fakaʻaiʻai ʻa e ʻea.
  2. ʻE lava ke tomuʻa ʻita ʻa e konga VialTweeter. Faʻo ʻa e konga VialTweeter (ko e sonotrode pe taʻe transducer!) ki he ʻaisi pe ʻaisi ke teuteu ke mokomoko ʻa e konga titanium ʻoku tokoni ke toloi ʻa e mafana ʻo e ʻea ʻi he sipinga. Kapau ʻe lava, ʻe lava ke tomuʻa ʻita foki mo e sipinga.
  3. Fakaʻaongaʻi ʻa e ʻaisi momoa ke mokomoko lolotonga e sonication. Fakaʻaongaʻi ha laulau mamaha ʻoku fonu ʻi he ʻaisi momoa pea tuku ʻa e VialTweeter ʻi he ʻaisi momoa ke lava ʻo molia vave ʻa e vela.

ʻOku fakaʻaongaʻi ʻe he kau fakatau fakaemamani lahi ʻa e VialTweeter mo e VialPress ki heʻenau sipinga teuteu fakaʻaho ʻi he ngaue totonu, biochemical, fakafaitoʻo mo kiliniki laboratories. Ko e polokalama fakakomipiuta mo e mafana ʻo e ʻea ʻoku ne puleʻi ʻa e UP200St processor, ʻoku reliably mapuleʻi ʻa e mafana mo e sipinga ʻo e ʻea vela ʻoku ne fakaʻehiʻehi mei ai. ʻOku hanga ʻe ultrasonic sipinga ʻo e teuteu mo e VialPress VialPress ʻo fakahaofi ha ngaahi ola falalaʻanga mo reproducible!

Fakaikiiki fakatekinikale ʻo e VialTweeter

Ko e VialTweeter ko ha konga sonotrode ia ʻoku ngaohi mei he titanium te ne lava ʻo hiki hake ki ha foʻi vai ʻe 10 ʻi he ngaahi ava ʻi he konga folofola. ʻIkai ngata ai, ʻe lava ke clamped ʻa e tiupi ki ha sivi lahi ange ʻe 5 ki he VialTweeter ʻi muʻa ʻo fakaʻaongaʻi ʻa e VialPress. ʻOku fokotuʻutuʻu ʻa e VialTweeter ke tufaki ʻa e ivi ultrasonication uniformly ki he foʻi vial takitaha ke fakapapauʻi ʻoku falalaʻanga mo faitaha sonication ngaahi ola. ʻOku liliu ʻe ha kiʻi hono pikiʻanga siʻisiʻi ʻa e VialTweeter sonotrode ki he kelekele pea fakatatau ʻa e tiupi ki he sivi hake.

Ngaahi lelei 'o e VialTweeter ha vakai nounou ki

  • Vials fakafonua'i he taimi tatau 'a e lahi 'o e sonication 'o a'u ki he 10
  • Sonication 'ikai fakahangatonu 'i he ma'olunga ultrasonic malohi 'o fakafou 'i he holisi 'a e ipu ki he sipinga 'o e
  • Na'e 'ai 'e sonication 'ikai fakahangatonu 'a hono faka'uli'i 'o e ngaahi kolosi pea mo e sipinga 'o e mole
  • Ngaahi ola koe'uhi ko adjustable mo controllable sonication amplitude
  • Na'e 'ai 'e he VialPress koe ke sonicate 'a e tiupi lahi ange
  • Adjustable amplitude mei he 20 ki he 100%
  • Founga 'o e sepo adjustable mei he 0 ki he 100%
  • autoclavable

ʻOku fakalelei ʻa e VialTweeter ʻe he UP200St, ko ha 200 Watts malohi ultrasonic processor. ʻOku fakanaunau ʻa e UP200St ʻaki ha polokalama fakakomipiuta fakapotopoto ʻoku ne fakaʻata ʻa e mapuleʻi totonu ʻo e ngaahi fakangatangata mahuʻinga ultrasonic hange ko e amplitude, taimi sonication, pulsation, mo e ʻea. ʻOku hoko heni ʻa e VialTweeter ko ha meʻangaue falalaʻanga ki he ola lelei reproducible ngaahi ola ʻo e founga totonu mo biochemical laboratories.
Lanu e ala faka'ali'ali ultrasonic me'angaue UP400StʻE lava ke fakatonutonu ʻa e Amplitude ʻi he vahaʻa ʻo e 20 mo e 100% pea fakaʻata ia ke liliu ʻa e ultrasonic malohi ki hoʻo sipinga. Hange ko ʻeni, ʻoku fie maʻu ʻe he kosi mo e fragmentation ʻo e DNA mo e RNA ha amplitude vaivai ke taʻofi ʻaki hono ngaohi ʻo ha fanga kiʻi konga iiki ʻo e DNA, ʻoku fie maʻu ʻe he homogenization ʻo e ʻuto ʻo e mausi ha malohi lahi sonication. Fili ʻa e amplitude lelei taha, sonication malohi mo e loloa ʻo fakafou ʻi he menu poto mo faingofua ʻi he UP200St processor. ʻE lava ke faingofua hono maʻu mo fakalele ʻo e menu mo e settings ʻo fakafou ʻi coloured lomiʻi ʻa e Display. Te ke lava ʻi he ngaahi feituʻu ko ia ʻo fokotuʻu ha ngaahi fakangatangata sonication hange ko e amplitude, pulsation/cycle Mode, sonication loloa, input fakakatoa ʻo e ivi, mo e ngaahi fakangatangata ʻo e ʻea. ʻI he fakatotolo mo e faiva, ʻoku mahuʻinga ʻa e repeatability ʻo e ngaahi ʻahiʻahi mo e sivi. ʻOku ʻuhinga ʻeni ʻoku matuʻaki mahuʻinga ʻaupito ʻa hono lekooti totonu ʻo e ngaahi tuʻunga ʻo e founga ngaue mo e sonication. ʻOku tohi ʻe he fakamatala fakahangatonu protocolling ʻa e fakamatala kotoa sonication ki ha faile CSV ʻi ha kaati SD koeʻuhi ke faingofua haʻo vakaiʻi mo fakafehoanaki ʻa e ngaahi sonication kehekehe. ʻE lava ke faingofua hono maʻu mo vahevahe ʻa e fakamatala ultrasonic kotoa pe ʻi he faile CSV.
ʻOku feinga ʻa Hielscher Ultrasonics ke ʻoatu kiate koe ʻa e tekinolosia fakalakalaka ke fakafaingofuaʻi mo fakaleleiʻi hoʻo ngaue fekumi!

Kole ke fai ha fokotu'u ki he me'a ni!

Ke ma'u atu ha fokotu'u, kataki 'o fakahu ho'o fakamatala fakaikiiki ki he founga fetu'utaki ki he foomu 'i lalo. 'Oku tomu'a fili ha-configuration me'angaue angamaheni. Ongo'i tau'ataina ke toe fakalelei'i 'a e fili ko ia kimu'a pea toki lomi'i 'i he ke kole 'a e e fokotu'u.








Kataki 'o fakahaa'i mai 'a e fakamatala, 'oku ke faka'amu ke ma'u, 'i lalo:



  • UP200St-G ultrasonic 'uhila 200 Watts

    mau maau ultrasonic, 200W, 26kHz (autom. fakatonutonu polokalama), lomi'i he screen, amplitude adjustable 20-100%, sepo 10-100%, momoa lele malu'i, IP51, incl. malohi e fua 'o e, socket ki he ethernet, me'akai fe'unga mo e malohi, netiueka keipolo, me'a to'oto'o, tohi lesoni



  • UP200St-m ultrasonic Transducer 200 Watts

    ultrasonic transducer, Ø45mm, approx. loloa 230mm, titanium ko e Me'aifi Hoane Ø10mm (amplitude 70µm), IP65 maka, 'a e me'a lomi/ta'ofi e kamata, socket ki he PT100, LEDs ki he sipinga 'o fakamama'i, mo ST1-Clamp, mo e feinga 'a e ngaahi me'angaue



  • Hielscher VialTweeter ki he ultrasonic device UP200St

    'Oku fai 'a e ki'i hina-Tweeter-Sonotrode 'o e titanium, he processor ultrasonic UP200St pe UP200Ht, 'i he 10 bores ø11mm, ki he excitation 'o e 10 hake ki Eppendorf tiupi 1.5ml pe ko e ni'ihi kehe, (vakai, clamping foki 'a e me'angaue VialPress ma'a e ngaahi vaka mo e ngaahi tafa'aki kehe)



  • sonotrode ki he sonication hangatonu, fai 'o e titanium, Ø2mm (3mm 2), approx. loloa 120mm, tangata filo M6x0.75, ki he sipinga ca. mei 2ml a'u ki he 50 ml, amplitude fika approx. 1:3, autoclavable



  • Hielscher e tata'o'anga ma'a VialTweeter 'i he ultrasonic me'angaue UP200St

    Clamping 'a e me'angaue ko ha accessory ki he VialTweeter-Sonotrode S26d11x10, stainless ukamea, ki he excitation 'o e ngaahi vaka hake ke 5 mo Ø 'o ha mm hake ke 20



  • me'a kamosi 'o e va'e mama'o

    Vakai ki he me'a kamosi e va'e mama'o, me'a malaki lomi, mo RJ45 palaki (tangata), 'uli'uli vali 'a e sitila mo ha ulapa, mita 'e 1.5 keipolo, ki he kotoa pe Hielscher ultrasonic homogenizers mo ala mapule'i (e.g. UP200Ht, UP200St, faka'ata remote control RJ45 'i he ngaahi tukunga), me'a kamosi 'o e va'e mama'o


Kataki 'o fakatokanga'i ange 'etau Tu'utu'uni totonu fakatautaha.


Ultrasonic me'angaue VialTweeter ki he to'o hingoa polotiini mei ha ngaahi sipinga 'o e kupu (lomi'i ke fakalahi!)

VialTweeter mo VialPress ki ha sonication ʻoku ʻikai fakahangatonu.

Ngaahi tohi/fakamo'oni fakafolofola



Ko e sitepu 3 ki he lavame'a Ultrasonic ngaue ki he: Feasibility - Optimization - me'afua-hake (lomi'i ke fakalahi!)

Ultrasonic processing: Hielscher tokoniʻi koe mei he feasibility mo e optimization ki he faiva fakakomesiale!